Energy Management & Asset O&M
Digital SCADA & analytics, preventive maintenance, decarbonization advisory for ESG & Net Zero targets.
What this is
What happens after commissioning, which is where most of a system’s life is spent and most of its yield is quietly lost.
A photovoltaic array degrades slowly and fails suddenly, and neither is visible from the ground. Soiling takes a few percent a month in a dusty season. A shaded or failed string can cost a fifth of an array’s output while the inverter still reports as running. Nothing about the site looks different on the day it happens — which is the entire argument for measuring rather than inspecting.
Where it fits
- Any commissioned system, whether or not it was originally built by us
- Portfolios across several sites, where comparison is what surfaces the outlier
- Organisations reporting on renewable generation for ESG or Net Zero commitments
- Assets approaching the end of an original EPC warranty period
What the work involves
- SCADA and remote monitoring, with alarms that reach someone who can act
- Performance-ratio tracking against the modelled yield for that site
- Scheduled preventive maintenance and module cleaning
- Thermographic inspection and string-level testing
- Inverter servicing, firmware currency and spares management
- Periodic reporting suitable for internal and disclosure use
Worth knowing
Performance ratio is the number that matters
Generation in kilowatt-hours tells you what the weather did. Performance ratio — actual output against what the irradiance at that site should have produced — tells you what the plant did, and is the only figure that makes a cloudy month and a soiled array distinguishable.
How every project runs
One accountable team from the first site visit to the maintenance years afterwards. Nothing is handed to a subcontractor at the seams.
- 01
Plan
- Energy Assessment
- Detailed Engineering
- Structural Design
- 02
Build
- Procurement
- Construction & QA
- 03
Energise & sustain
- Grid Connectivity
- Commissioning
- Long-Term O&M
Where we have done this
All projects11 MWp
Club Mahindra Resorts
Pan India — multiple locations
2 MWp
Electronics Corporation of India Limited (ECIL)
Hyderabad, Telangana
1.2 MWp
Bharat Electronics Limited (BEL)
Machilipatnam, Andhra Pradesh
500 kWp
Karnataka Legislative Assembly (Vidhana Soudha)